Proline Prosonic Flow B 200 HART
Endress+Hauser
Function scope
• A total of 1000 measured values can be stored
• 4 logging channels
• Adjustable logging interval for data logging
• Display of the measured value trend for each logging channel in the form of a chart
29
Chart of a measured value trend
• x-axis: depending on the number of channels selected displays 250 to 1000 measured
values of a process variable.
• y-axis: displays the approximate measured value span and constantly adapts this to the
ongoing measurement.
If the length of the logging interval or the assignment of the process variables to the
channels is changed, the content of the data logging is deleted.
Navigation
"Diagnostics" menu → Data logging
"Data logging" submenu
‣
Data logging
Assign channel 1
Assign channel 2
Assign channel 3
Assign channel 4
Logging interval
Clear logging data
‣
Display channel 1
‣
Display channel 2
‣
Display channel 3
‣
Display channel 4
Operation
A0016222
103