Commissioning
Parameter
Operating mode
Assign frequency output
Minimum frequency value
72
Parameter overview with brief description
Prerequsite
–
The Frequency option is
selected in the Operating
mode parameter (→ 69).
One of the following options is
selected in the Assign
frequency output parameter
(→ 72):
• Volume flow
• Corrected volume flow
• Corrected methane volume
*
flow
• Mass flow
*
• Energy flow
*
• Methane fraction
*
• Wobbe index
*
• Calorific value
*
• Temperature
• Sound velocity
• Flow velocity
*
• Acceptance rate
*
• Signal asymmetry
*
• Turbulence
*
• Signal strength
*
• Signal to noise ratio
Description
Define the output as a pulse,
frequency or switch output.
Select process variable for
frequency output.
Enter minimum frequency.
Proline Prosonic Flow B 200 HART
Selection / User
Factory setting
entry
• Pulse
Pulse
• Frequency
• Switch
• Off
Off
• Volume flow
• Corrected volume
flow
• Corrected methane
*
volume flow
• Mass flow
*
• Energy flow
*
• Methane fraction
*
• Wobbe index
*
• Calorific value
*
• Temperature
• Sound velocity
• Flow velocity
*
• Acceptance rate
*
• Signal asymmetry
*
• Turbulence
*
• Signal strength
• Signal to noise
*
ratio
0 to 1 000 Hz
0 Hz
Endress+Hauser
Need help?
Do you have a question about the Proline Prosonic Flow B 200 and is the answer not in the manual?
Questions and answers