Commissioning
Parameter
Format display
Value 1 display
0% bargraph value 1
100% bargraph value 1
Value 2 display
Value 3 display
0% bargraph value 3
100% bargraph value 3
Value 4 display
*
Visibility depends on order options or device settings
80
Parameter overview with brief description
Prerequsite
A local display is provided.
A local display is provided.
A local display is provided.
A local display is provided.
A local display is provided.
A local display is provided.
A selection has been made in
the Value 3 display
parameter.
An option was selected in the
Value 3 display parameter.
A local display is provided.
10.4.8
Configuring the output conditioning
The Output conditioning wizard guides you systematically through all the parameters
that have to be set for configuring the output conditioning.
Description
Select how measured values
are shown on the display.
Select the measured value that
is shown on the local display.
Enter 0% value for bar graph
display.
Enter 100% value for bar
graph display.
Select the measured value that
is shown on the local display.
Select the measured value that
is shown on the local display.
Enter 0% value for bar graph
display.
Enter 100% value for bar
graph display.
Select the measured value that
is shown on the local display.
Proline Prosonic Flow B 200 HART
Selection / User
Factory setting
entry
• 1 value, max. size
1 value, max. size
• 1 bargraph + 1
value
• 2 values
• 1 value large + 2
values
• 4 values
• Volume flow
Volume flow
• Corrected volume
flow
• Corrected methane
*
volume flow
• Mass flow
*
• Energy flow
*
• Methane fraction
*
• Calorific value
*
• Wobbe index
*
• Temperature
• Totalizer 1
• Totalizer 2
• Totalizer 3
• Current output 1
*
• Current output 2
• Sound velocity
• Flow velocity
*
• Acceptance rate
*
• Signal asymmetry
*
• Turbulence
*
• Signal strength
• Signal to noise
*
ratio
Signed floating-point
Country-specific:
number
• 0 m³/h
• 0 ft³/h
Signed floating-point
Depends on country
number
and nominal
diameter
Picklist see Value 1
None
display parameter
Picklist see Value 1
None
display parameter
Signed floating-point
Country-specific:
number
• 0 m³/h
• 0 ft³/h
Signed floating-point
Depends on country
number
and nominal
diameter
Picklist see Value 1
None
display parameter
Endress+Hauser