Electrical connection
30
Pulse/frequency output
1
_
+
12345
 8
Connection example for pulse/frequency output (passive)
1
Automation system with pulse/frequency input (e.g. PLC)
2
Power supply
3
Transmitter: observe input values
Switch output
1
_
+
 9
Connection example for switch output (passive)
1
Automation system with switch input (e.g. PLC)
2
Power supply
3
Transmitter: observe input values
Current input
 10
Connection example for 4-20 mA current input
1
Power supply
2
External measuring device (for capturing the pressure)
3
Transmitter: observe input values →  131