sataSsdTest ................................................. PASS
Starting test: showTemperature ......
+Board First Thermal Monitor Sensor[0] is 38.0 C
+Board First Thermal Monitor Sensor[1] is 33.0 C
+Board First Thermal Monitor Sensor[2] is 31.0 C
+Board First Thermal Monitor Sensor[3] is 38.0 C
+Board First Thermal Monitor Sensor[4] is 34.0 C
+Board Second Thermal Monitor Sensor[0] is 40.0 C
+Board Second Thermal Monitor Sensor[1] is 45.0 C
+Board Second Thermal Monitor Sensor[2] is 36.0 C
+Board Second Thermal Monitor Sensor[3] is 34.0 C
+Board Second Thermal Monitor Sensor[4] is 35.0 C
Sensor Temperature : 27 c
Sensor Temperature : 31 c
DDR Temperature
33 c
showTemperature ............................................. PASS
Starting test: slotInfoTest ......RPM Slot No 0
slotInfoTest ................................................ PASS
spiFlashAccessTest .......................................... PASS
Starting test: udfAccessTest ......
+ Access Test for unit 0 : PASSED
udfAccessTest ............................................... PASS
Starting test: usbTest ......
-USB "/dev/rsd0d" is not plugged/mounted/formatted; test SKIPPED
usbTest ..................................................... FAIL
cpldRWTest .................................................. PASS
extCPLDRWTest ............................................... PASS
fanCntrlAccessTest .......................................... PASS
Starting test: fanCntrlSpeedTest ......
ERROR: Tray[0] fan[0] speed 57% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[0]
FAN TRAY[0] FAN 0
ERROR: Tray[0] fan[1] speed 57% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[0]
FAN TRAY[0] FAN 1
ERROR: Tray[0] fan[2] speed 56% is out of expected range [80-100%]
ERROR: Tray[0] fan[2] speed 41% is out of expected range [50-70%]
ERROR: Fan speed variation failed for tray[0]
FAN TRAY[0] FAN 2
ERROR: Tray[0] fan[3] speed 56% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[0]
FAN TRAY[0] FAN 3
ERROR: Tray[1] fan[0] speed 57% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[1]
FAN TRAY[1] FAN 0
ERROR: Tray[1] fan[1] speed 57% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[1]
FAN TRAY[1] FAN 1
ERROR: Tray[1] fan[2] speed 56% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[1]
FAN TRAY[1] FAN 2
ERROR: Tray[1] fan[3] speed 57% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[1]
FAN TRAY[1] FAN 3
ERROR: Tray[2] fan[0] speed 57% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[2]
FAN TRAY[2] FAN 0
ERROR: Tray[2] fan[1] speed 57% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[2]
FAN TRAY[2] FAN 1
LEVEL 1 DIAGNOSTIC
Controller Speed Test FAIL
Controller Speed Test FAIL
Controller Speed Test FAIL
Controller Speed Test FAIL
Controller Speed Test FAIL
Controller Speed Test FAIL
Controller Speed Test FAIL
Controller Speed Test FAIL
Controller Speed Test FAIL
Controller Speed Test FAIL
Debugging and Diagnostics