Displaying A Remote-Port Mirroring Configuration - Dell C9000 Series Networking Configuration Manual

Hide thumbs Also See for C9000 Series:
Table of Contents

Advertisement

You can use the default VLAN and native VLANs as a source VLAN.
You cannot configure the dedicated VLAN used to transport mirrored traffic as a source VLAN.
Egressing remote-vlan packets are rate limited to a default value of 100 Mbps.
In a destination session used for remote port mirroring:
Maximum number of destination sessions supported on a switch: 64
Maximum number ports supported in a destination session: 64.
You can configure any port as a destination port.
You can configure additional destination ports in an active session.
You can tunnel the mirrored traffic from multiple remote-port source sessions to the same destination
port.
By default, destination port sends the mirror traffic to the probe port by stripping off the rpm header. We
can also configure the destination port to send the mirror traffic with the rpm header intact in the
original mirror traffic..
By default, ingress traffic on a destination port is dropped.
Restrictions
When you configure remote port mirroring, the following restrictions apply:
You can configure the same source port to be used in multiple source sessions.
You cannot configure a source port channel or source VLAN in a source session if the port channel or
VLAN has a member port that is configured as a destination port in a remote-port mirroring session.
A destination port for remote port mirroring cannot be used as a source port, including the session in
which the port functions as the destination port.
A destination port cannot be used in any spanning tree instance.
The reserved VLAN used to transport mirrored traffic must be a L2 VLAN. L3 VLANs are not supported.
Displaying a Remote-Port Mirroring
Configuration
To display the current configuration of remote port mirroring for a specified session, enter the show config
command in MONITOR SESSION configuration mode.
Dell(conf-mon-sess-2)#show config
!
monitor session 2 type rpm
source fortyGigE 0/60 destination remote-vlan 300 direction rx
source Port-channel 10 destination remote-vlan 300 direction rx
no disable
To display the currently configured source and destination sessions for remote port mirroring on a switch,
enter the show monitor session command in EXEC Privilege mode.
Dell(conf)#do show monitor session
SessID
Source
------
------
1
remote-vlan 100
1
remote-vlan 100
2
Fo 0/60
2
Po 10
Destination
-----------
Fo 0/48
Po 100
remote-vlan 300
remote-vlan 300
Dir
Mode
Source IP
---
----
---------
N/A
N/A
N/A
N/A
N/A
N/A
rx
Port
N/A
rx
Port
N/A
Dest IP
--------
N/A
N/A
N/A
N/A
Port Monitoring
865

Advertisement

Table of Contents
loading