The following example shows the show diag in control processor command.
Dell#show diag cp unit detail
Diag status of CP unit:
--------------------------------------------------------------------------
Board: C9010 Dell Networking
=================================================
CP unit is currently offline.
CP unit alllevels diag issued at Sun Apr 26, 2015 10:32:01 PM.
Current diag status
Duration of execution (Total) : 4 min 0 sec.
Diagnostic test results located:
Last notification received at Sun Apr 26, 2015 10:36:01 PM
--------------------------------------------------------------------------
DELL
DIAGNOSTICS-C9000-CP00
CpuType
PPID
PPID Rev
Service Tag
Part Number
Part Number Revision
RPM CPLD
RPM extended CPLD
SW Version
Available free memory: 1,357,742,080 bytes
biosVerGetTest .............................................. PASS
boardRevisionTest ........................................... PASS
Starting test: cpldAccessTest ......CPLD Major Ver 3 Minor Ver 3
cpldAccessTest .............................................. PASS
Starting test: cpuGELinkStatusTest ......
+ GbE1 Link Status UP
+ GbE2 Link Status DOWN
+ GbE3 Link Status UP
cpuGELinkStatusTest ......................................... FAIL
cpuRevisionTest ............................................. PASS
cpuSdramPresenceTest ........................................ PASS
cpuSdramSizeTest ............................................ PASS
eepromTest .................................................. PASS
Starting test: extendedCPLDAccessTest ......extended CPLD Major Ver 2 Minor Ver 3
extendedCPLDAccessTest ...................................... PASS
fanAirFlowDirection ......................................... PASS
fanPresenceTest ............................................. PASS
fpgaAccessTest .............................................. PASS
Starting test: i2cTest ......
ERROR: ioctl: "psu0" op(1)=READ WITH STOP bus=7 address=0x70 offset=0xd7 length=1
ERROR: ioctl: "psu1" op(1)=READ WITH STOP bus=8 address=0x71 offset=0xd7 length=1
ERROR: ioctl: "psu2" op(1)=READ WITH STOP bus=9 address=0x72 offset=0xd7 length=1
ERROR: ioctl: "lm0" op(1)=READ WITH STOP bus=17 address=0x42 offset=0 length=1
ERROR: ioctl: "lm2" op(1)=READ WITH STOP bus=19 address=0x44 offset=0 length=1
ERROR: ioctl: "lm3" op(1)=READ WITH STOP bus=20 address=0x45 offset=0 length=1
: Card diags are done.
-- RPM-CP
-- CN0CKKCP7793149U0047
-- X00
-- 154RG02
-- 0CKKCP
-- X00
--
--
-- 1-0(0-4854)
LEVEL 0 DIAGNOSTIC
flash:/TestReport-CP-unit.txt
[0]
33
32
Debugging and Diagnostics