Division - Rigol MSO4000 User Manual

Digital oscilloscope
Hide thumbs Also See for MSO4000:
Table of Contents

Advertisement

RIGOL

Division

Divide the waveform voltage values of signal source A by that of source B point by
point and display the results. It can be used to analyze the multiple relationships of
waveforms in two channels. Note that when the voltage value of channel B is 0, the
result of the division is treated as 0.
Press MATH  Operate to select "A ÷ B":
Press Source A and Source B to select the desired channels. The channels
available are CH1, CH2, CH3 and CH4.
Press
and use
Press
and use
Press Invert to turn the inverted display of the operation results on or off.
HORIZONTAL
used to adjust the horizontal position and scale of the operation results.
6-4
to adjust the vertical position of the operation results.
to adjust the vertical scale of the operation results.
POSITION and HORIZONTAL
6 To Make Measurements
SCALE can also be
MSO4000/DS4000 User's Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds4000

Table of Contents