Can Decoding (Option) - Rigol MSO4000 User Manual

Digital oscilloscope
Hide thumbs Also See for MSO4000:
Table of Contents

Advertisement

RIGOL

CAN Decoding (Option)

Press Decode1  Decode and select "CAN" to open the CAN decoding function
menu.
1. Source
Press Source and select any channel (CH1-CH4 or D0-D15) as the source
channel.
2. Signal Type
Press Signal Type to select the desired signal type.
CAN_H: the actual CAN_H bus signal.
CAN_L: the actual CAN_L bus signal.
Differential: the CAN differential bus signals connected to an analog
channel using a differential probe. The positive lead of the probe connects
CAN_H and the negative lead connects CAN_L.
3. Baud
Press Baud to select a baud rate (100 kb/s, 125 kb/s, 250 kb/s, 400 kb/s, 500
kb/s, 800 kb/s, 1 Mb/s or User) that matches the CAN bus signal. When "User" is
selected, press Setup and use
10 kb/s to 1 Mb/s.
4. Sample Point
The Sample point is a point within a bit's time. The oscilloscope samples the bit
level at this point. "Sample point" is represented by the percentage of "the time
from the start of the bit's time to the sample point time" in the "bit's time".
Press Sample Point and use
The range is from 5% to 95%.
8-16
to enter the desired rate, the range is from
to adjust this parameter with a step of 1%.
1bit
60%
70%
80%
8 Protocol Decoding
MSO4000/DS4000 User's Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds4000

Table of Contents