RIGOL
1. Select Measurement Source
Press Cursor A to select the waveform of analog channels (CH1 to CH4) or
math operation results (MATH) as the measurement source of cursor A (only
channels enabled are available). You can also select "None", namely do not use
cursor A.
Press Cursor B to select the waveform of analog channels (CH1 to CH4) or
math operation results (MATH) as the measurement source of cursor B (only
channels enabled are available). You can also select "None", namely do not use
cursor B.
2. Adjust Cursor Position (note that you can also press
to switch the current cursor)
Adjust cursor A: press CursorA and use
A. During the adjustment, the measurement result will change accordingly.
The adjustable range is limited within the screen.
Adjust cursor B: press CursorB and use
B. During the adjustment, the measurement result will change accordingly.
The adjustable range is limited within the screen.
Adjust cursor A and B at the same time: press CursorAB and use
adjust the position of cursor A and B at the same time. During the
adjustment, the measurement results will change accordingly. The
adjustable range is limited within the screen.
Note: The vertical cursor will track the marked point (namely jumps up and
down with the transient change of the waveform). Thus, the Y value might
change even though you do not adjust the cursor.
3. Measurement Example
Use cursor A and B to measure the waveforms of CH1 and CH2 respectively. You
would discover that the cursors would track the marked points when the
waveforms are expanded or compressed horizontally.
6-32
6 To Make Measurements
continuously
to adjust the position of cursor
to adjust the position of cursor
MSO4000/DS4000 User's Guide