GeoCOM Reference Manual
Parameters
POSMode
ATRMode
bDummy
Return-Codes
General:
RC_OK
RC_IVPARAM
AUT_RC_DETENT_ERROR
AUT_RC_TIMEOUT
AUT_RC_MOTOR_ERROR
AUT_RC_ANGLE_ERROR
TPS1100 - Version 1.05
In
Position mode:
AUT_NORMAL
the compensator. For values >25GON
positioning might tend to inexact.
AUT_PRECISE
inclination of target. Tends to long
position time (check
and/or COM-time out if necessary).
In
Mode of ATR:
AUT_POSITION
other face.
AUT_TARGET:
target in the destination area. This set is
only possible if ATR exists and is
activated.
In
It's reserved for future use, set
always to
Execution successful.
Invalid parameter.
Destination angle lies in the illegal sector,
collision is occurred. Set new Destination
angle.
Timeout while positioning of one or both
axes. (perhaps increase AUT timeout, see
AUT_SetTimeout
Instrument has no 'motorization'.
Error within angle measurement. Maybe
instrument is not levelled and not stable.
Try to correct instrument's position or
switch automatic incline correction to
(see
TMC_SetInclineSwitch
Automation - AUT
: uses the current value of
: tries to measure exact
AUT_TIMEOUT
: conventional position to
tries to position onto a
FALSE
)
bDummy
OFF
).
7-20