Leica tps1100 Reference Manual page 66

Hide thumbs Also See for tps1100:
Table of Contents

Advertisement

GeoCOM Reference Manual
}
Fine-adjust Position Mode
enum AUT_ADJMODE
{
AUT_NORM_MODE = 0
AUT_POINT_MODE
AUT_DEFINE_MODE = 2
}
Automatic Target Recognition Mode
enum AUT_ATRMODE
{
AUT_POSITION = 0,
AUT_TARGET = 1
}
Automatic Detent Mode
struct AUT_DETENT
{
double dPositiveDetent;
double dNegativeDetent;
BOOLE bActive;
}
TPS1100 - Version 1.05
//
for the positioning
// Possible settings of the positioning
// tolerance relating the angle- or the
// point- accuracy at the fine adjust.
// Angle tolerance
= 1
// Point tolerance
// System independent positioning
// tolerance. Set with AUT_SetTol
// Possible modes of the target
// recognition
// Positioning to the hz- and v-angle
// Positioning to a target in the
// environment of the hz- and v-angle.
// Detent data
// Detent in positive direction
// Detent in negative direction
// Is detent active
Automation - AUT
7-9

Hide quick links:

Advertisement

Table of Contents
loading