Leica tps1100 Reference Manual page 72

Hide thumbs Also See for tps1100:
Table of Contents

Advertisement

GeoCOM Reference Manual
7.3.5
AUT_MakePositioning - Turns telescope to specified position
AUT_Ma kePositio ning ....................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... 9027
9027 ................................................................................................................................................................................................................................................................AUT_Ma kePositio ning
C-Declaration
AUT_MakePositioning(double Hz,
VB-Declaration
VB_AUT_MakePositioning4(Hz As Double,
ASCII-Request
%R1Q,9027:Hz,V,PosMode,ATRMode,0
ASCII-Response
%R1P,0,0:RC
Remarks
This procedure turns the telescope absolute to the in
position, taking tolerance settings for positioning (see
account. Any active control function is terminated by this function call.
If the position mode is set to normal (
assumed that the current value of the compensator measurement is valid.
Positioning precise (
compensator measurement at the specified position and includes this
information for positioning.
If ATR is possible and activated and the ATR mode is set to
the instrument tries to position onto a target in the destination area. In
addition, the target is locked after positioning if the
the Lock status not set, the manual driving wheel is activated after the
positioning.
Parameters
Hz
V
TPS1100 - Version 1.05
double V,
AUT_POSMODE POSMode,
AUT_ATRMODE ATRMode,
BOOLE bDummy)
V As Double,
POSMode As Long,
ATRMode As Long,
bDummy As Boolean)
PosMode = AUT_PRECISE
In
Horizontal (telescope) position [
In
Vertical (instrument) position [
Hz
PosMode = AUT_NORMAL
) forces a new
LockIn
Automation - AUT
and
specified
V
) into
AUT_POSTOL
) it is
AUT_TARGET,
status is set. If
].
rad
].
rad
7-15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents