GeoCOM Reference Manual
ASCII-Request
%R1Q,20001:Volume[short]
ASCII-Response
%R1P,0,0:RC
Remarks
This function switches on the beep-signal with the intensity
continuous signal is active, it will be stopped first. Turn off the beeping
device with
Parameters
nIntens
Return Codes
RC_OK
See Also
IOS_BeepOff, BMM_BeepAlarm, BMM_BeepNormal
Example
IOS_BeepOn(IOS_BEEP_STDINTENS)
// wait for a second
IOS_BeepOff();
9.2.4
IOS_BeepOff - Stop active beep-signal
IOS_BeepOff....................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... 20000
20000 ...............................................................................................................................................................................................................................................................IOS_BeepOff
C-Declaration
IOS_BeepOff(void)
VB-Declaration
VB_IOS_BeepOff()
ASCII-Request
%R1Q,20000:
ASCII-Response
%R1P,0,0:RC
Remarks
This function switches off the beep-signal.
TPS1100 - Version 1.05
.
IOS_BeepOff
in
always
Basic Man Machine Interface - BMM
Intensity of the beep-signal (volume)
expressed as a percentage.
Default value is 100 %
. If a
nIntens
9-3