Leica tps1100 Reference Manual page 178

Hide thumbs Also See for tps1100:
Table of Contents

Advertisement

GeoCOM Reference Manual
Remarks
This function is used to orientates the instrument in Hz direction. It is a
combination of an angle measurement to get the Hz offset and afterwards
setting the angle Hz offset in order to orientates onto a target. Before the
new orientation can be set an existing distance must be cleared (use
TMC_DoMeasure
Parameters
HzOrientation
Return Codes
RC_OK
TMC_NO_FULL_CORRECTION
TMC_ACCURACY_GUARANTEE
TMC_ANGLE_ERROR
TMC_BUSY
TPS1100 - Version 1.05
Theodolite Measurement and Calculation - TMC
with the
command = TMC_CLEAR
in
Hz Orientation [rad]
Execution successful.
The orientation is set but not corrected by
all active sensors.
In order to secure witch correction is
missing use the both functions
TMC_IfDataAzeCorrError
TMC_IfDataIncCorrError
This message is to be considers as
warning.
The orientation is set but the accuracy is
not guarantee, because the result
consisting of measuring data which
accuracy could not be verified by the
system
You can a forced incline measurement
perform or switch off the incline.
This message is to be considers as info.
Problems with angle res. incline sensor. A
valid angle could not be measured. The
orientation is not set.
At repeated occur call service.
TMC resource is locked respectively
TMC task is busy or a distance is existing.
).
and