[ 324]
SLI GAIN
9 5 B
Adjusts the receive sensitivities for each port of the
port can be adjusted but the actual sensitivity are applied in the unit of card. To reflect the
changed value, the download process should be carried out after setting a desired sensitiv-
ity for each port.
CONDITIONS
16SLI2 cards and 4SLM
DEFAULT DATA
-1.5dB
A CTION
4 9 3 B
1) Press the [Transfer] button and [324] button.
2) Enter the number of the first port of the
card.(e.g., 201). Or, press the [Volume] button to se-
lect the number of the first port of the
press the [Right] Soft button and move the cursor.
3) Enter the port number whose sensitivity is changed.
Or, press the [Volume] button to select a desired port
number and press the [Right] soft button to move the
cursor.
4) Enter a receive sensitivity (([0]-[9]: -7~+11 dB).
Or, press the [Volume] button to select a desired re-
ceive sensitivity and press the [Right] soft button to
move the cursor.
5) Enter the Download item number (00) to apply the
actually changed sensitivities to each port.
Or, press the [Volume] button to select a Download
item and press the [Right] Soft button to move the
cursor.
6) Enter Download Check ([0]:NO,[1]:YES).
Or, press the [volume] button to select the
Download Check and press the [Right] Soft button.
Samsung Business Communications
are applied.
SLI
CHAPTER 2. MMC Programming
SLI
card. The receive sensitivity by
DISPLAY
[
2
0 1]
SLI
U
U
DOWNLOAD
SLI
[201]
SLI
D
O WNLOAD
U
U
card and
[201]
SLI
0
1 :-1.5dB -1.5dB
U
U
[201]
SLI
0
1 :-1.5dB +1 dB
U
U
[201]
SLI
DOWNLOAD
[201]
SLI
DOWNLOAD
GAIN
? NO
GAIN
? NO
GAIN
GAIN
GAIN
?
N
O
U
U
GAIN
?
Y
E S
U
U
2-99