500] System-Wide Counters - Samsung OfficeServ 7000 Series Programming Manual

Hide thumbs Also See for OfficeServ 7000 Series:
Table of Contents

Advertisement

CHAPTER 2. MMC Programming

[ 500] SYSTEM-WIDE COUNTERS

1 2 9 B
Used to set the values of the system counters. The counters are listed below with a brief
description of each.
No
Counter
0
ALARM REM.
CNTER
1
AUTO RDL
COUNTER
2
DISA CALL CNTER
3
DISA LOCK CNTER
4
NEW CALL
COUNTER
5
UCDS VISUAL
ALARM
6
UCDS AUDIO ALARM
7
UCD CS LEVEL 1
8
UCD CS LEVEL 2
D EFAULT DATA
6 1 2 B
SEE DESCRIPTION
A CTION
6 1 3 B
1) Press Transfer button and enter 500.
Display shows:
2-156
Default
5
The number of times that an alarm reminder will
ring a station before cancelling. RANGE = 1-99.
5
The number of times the system will redial an
outside number after the auto redial feature has
been activated. RANGE = 1-99.
99
Sets the maximum number of intercom calls that
can be made after accessing a DISA line.
RANGE = 1-99.
3
Number of attempts the system will allow to
incorrectly access a DISA line before locking out
the DISA line. RANGE = -99
99
Number of times the system will allow a user to
signal New Call on a Trunk line during one call.
RANGE = 1-99.
0
Used to set the Visual alarm threshold. It is
triggered when the number of calls waiting to be
answered in the UCD group reaches this value.
RANGE = 0-25.
0
Used to set the Audio alarm threshold. It is
triggered when the number of calls waiting to be
answered in the UCD group reaches this value.
RANGE = 0-25.
0
Provides call wait indication level 1 if number of
calls waiting to be answered in UCD group reaches
this value. RANGE = 0-25.
0
Provides call wait indication level 2 if number of
calls waiting to be answered in UCD group reaches
this value. RANGE = 0-25.
Description
DISPLAY
ALARM REM.CNTER
05
Samsung Business Communications

Advertisement

Table of Contents
loading

Table of Contents