[324] SLI2 GAIN

Adjusts the receive sensitivities for each port of the SLI2 card. The receive sensitivity by
port can be adjusted but the actual sensitivity are applied in the unit of card. To reflect the
changed value, the download process should be carried out after setting a desired
sensitivity for each port.
CONDITIONS
Only 16SLI2 cards are applied.
DEFAULT DATA
-1.5 dB
ACTION
1) Press the Transfer button and 324.
2) Enter the number of the first port of the SLI2 card.
(e.g., 201). Or, press the Volume button to select the
number of the first port of the SLI2 card and press the
Right Soft button and move the cursor.
3) Enter the port number whose sensitivity is changed.
Or, press the Volume button to select a desired port
number and press the Right soft button to move the
cursor.
4) Enter a receive sensitivity ([0]-[9]: LEVEL 0~9).
Or, press the[Volume button to select a desired
receive sensitivity and press the Right soft button to
move the cursor.
5) Enter the Download item number (00) to apply the
actually changed sensitivities to each port.
Or, press the Volume button to select a Download
item and press the Right Soft button to move the
cursor.
6) Enter Download Check ([0]: NO, [1]: YES).
Or, press the Volume button to select the
Download Check and press the Right Soft button.
RELATED ITEMS
None
© SAMSUNG Electronics Co., Ltd.
OfficeServ 7000 Series Call Server Programming Manual
DISPLAY
[201] SLI2 GAIN
DOWNLOAD
[201] SLI2 GAIN
DOWNLOAD
[201] SLI2 GAIN
01:LEVEL 3  3
[201] SLI2 GAIN
01:LEVEL 3  4
[201] SLI2 GAIN
DOWNLOAD
[201] SLI2 GAIN
DOWNLOAD
? NO
? NO
? NO
?YES
2-105

Advertisement

Table of Contents
loading

Table of Contents