Samsung OfficeServ 7000 Series Programming Manual page 444

Hide thumbs Also See for OfficeServ 7000 Series:
Table of Contents

Advertisement

CHAPTER 2. MMC Programming
No
Code
MNG--
89
MNG01
90
MNG02
91
MNG03
92
MNG04
93
MNG05
94
MNG06
D EFAULT DATA
1 0 2 0 B
ALL OFF
A CTION
1 0 2 1 B
1) Press Transfer button and enter 852.
Display shows:
2) Enter desired Alarm Display number.(e.g., 64)
OR
Press Volume buttons to select desired option and
press Right Soft button to advance the cursor.
3) To select if the alarm is active, press 1 for
YES and 0 for NO.
An entry will return the cursor to step 2.
OR
Press Volume buttons to make selection and press
Right Soft button to save and return to step 2.
4) Press Transfer button to save and exit.
OR
Press Speaker button to advance to next MMC.
2-402
Alarm Name
Minor Error
Minor Fault without Alarm Buffer saving
Phone Discon-
Indicates the Phone is disconnected.
nect
Alarm Data = Tel number or Cx-Syy-Pzz
Phone Connect
Indicates the Phone is connected.
Alarm Data = Tel number or Cx-Syy-Pzz
Off Hook Alarm
Indicates Extension Off Hook Alarm timer has expired.
Alarm Data = Tel number or Cx-Syy-Pzz
On Hook
Indicates the Off Hook Alarm Extension is on hook.
Alarm Data = Tel number or Cx-Syy-Pzz
MGI Packet Loss
Indicates the MGI connection RTP packet loss is more
than 10 %.
Alarm Data = Tel number or Cx-Syy-Pzz
MGI Packet Delay
Indicates the MGI connection RTP packet delay is more
than 500 ms.
Alarm Data = Tel number or Cx-Syy-Pzz
(continued)
Definition
DISPLAY
01:MJA01 ACT:OFF
POR Restart
64:MNF01 ACT:OFF
Card Out
64:MNF01 ACT:ON
Card Out
Samsung Business Communications