CHAPTER 2. MMC Programming
21
IMPS SERVER ADDR
22
QoS CHECK
SERVER
ETHERNET PARAMETERS
- The first three parameters: SYSTEM IP ADDR, SYSTEM GATEWAY, and
- When changing any IP address/value, three digits must be entered for
C ONDITIONS
9 5 8 B
This MMC must be used if there are ITP phones and/or MGI cards on the system.
After changing Ethernet parameters, restart the system to apply the new settings.
2-340
Specify an IMPS SER SERVER IP address.
OfficeServ 7400 only supports IMPS SERVER Server
Specify a QoS CHECK SERVER IP address.
SYSTEM NET MASK are stored separately from the main system database and
thus will not be defaulted when MMC811 'CLEAR MEMORY' is performed.
Furthermore, any changes to these parameters will not be applied until the
MP40/MCP/MP10 is reset.
each(octet) field. For example 192.168.1.10 should be entered as: 192 168 001
010.