851] Alarm Reporting - Samsung OfficeServ 7000 Series Programming Manual

Hide thumbs Also See for OfficeServ 7000 Series:
Table of Contents

Advertisement

[ 851] ALARM REPORTING

2 5 1 B
This MMC is used to view, store, print or clear system alarms. Two levels of faults are dis-
played via an alarm code: major alarms and minor alarms. Major alarms codes are usually
service affecting and require a certified technician to determine the fault. A minor alarm in-
dicates a fault that may or may not be service affecting and usually does not seriously de-
grade the system's operating capabilities.
The alarm buffer holds up to 100 alarms on a First In-First Out(FIFO) basis. Alarms pro-
vide a date and time stamp based on the system time. If applicable, the hardware cabinet,
port, and/or slot will be displayed. If an ALARM SIO port is programmed(MMC 804),
alarm information can be printed on demand and as it is provided.
A LARM REPORTING OPTIONS(Select one of the options)
1 1 0 3 B
No
0
VIEW ALARMS
1
OVERFLOW
CONTROL
2
CLEAR ALARM BUF
3
PRINT ALARM BUF
ALARM CODE DEFINITION
See Alarm Code Definitions in MMC 852.
D EFAULT DATA
1 0 1 7 B
NONE
A CTION
1 0 1 8 B
1) Press Transfer button and enter 851.
Display shows:
2) Enter desired option.
OR
Press Volume button to make selection and press
Right Soft button to move cursor.
Samsung Business Communications
Option
View alarm buffer.
Determines buffer control when buffer is full.
0 OVERWRITTEN: When buffer is full, the oldest entry in
buffer is overwritten.(Default.)
1 STOP RECORDING: When buffer is full, stop recording
alarms.
Clears alarm buffer.
Prints contents of alarm buffer to the assigned alarm IO port.
CHAPTER 2. MMC Programming
Description
DISPLAY
SYS ALARM REPORT
V
I EW ALARMS
U
U
SYS ALARM REPORT
V
I EW ALARMS
U
U
2-395

Advertisement

Table of Contents
loading