CHAPTER 2. MMC Programming
No
Option
2
OVERFLOW
3
GROUP
TRANSFER
4
NEXT PORT
5
MEMBER
6
NEXT HUNT
7
GROUP BUSY
8
GROUP AUTO
ANS
9
ALLOUT NEXT
10
RBT MSG
Calls to a group
Calls to a group do not follow the call forwarding instructions of any station in the
group.
2-186
This is the timer value that will cause unanswered calls to a group to
begin also ringing the NEXT PORT(see below) after this timer has
elapsed. If set to 000, no overflow will take place.
This is a timer that will determine how long Trunk Line calls transferred
to the group will ring at the group before recalling. If set to 000, no recall
will take place.
This is the station or group number that callers will also ring at if the
OVERFLOW feature has been programmed. The OVERFLOW
DESTINATION can be defined as:
1 COMMON BELL There is a common bell port on each MIS card.
2 RING OVER PAGE The ROP port can be defined as the NEXT port.
3 STATION OR STATION GROUP. Any station or station group can be
defined as the NEXT port.
List all members that are to be in the group. Up to 48 members for the
system are allowed in each group, but stations can be assigned to
multiple station groups.
The length of time a call will ring at a station before it hunts to the next
group member.
When this option is set to ON, a busy signal will be sent to the caller if
all group members are busy. When this option is set to OFF, the ring
back tone is sent to the caller even if all group members are busy. UCD
is an exception to this rule. This option only works when MMC 210 SGR
INC BUSY is set to OFF. When MMC 210 SGR INC BUSY is set to ON,
all station groups will follow this setting.
If set ON, stations will automatically answer calls to the group(when ring
type is DISTRIBUTED or SEQUENTIAL)
This is the option to designate whether to transfer the call directly to the
extension (group) designated in the NEXT PORT without waiting during
the OVERFLOW time when all the members of the extension group are
in logged out status. (OFF/ON)
This is used when executing the coloring service for the extension
group.
Enter the VMS message number which is to be used for coloring. In
case of the F-STN, this operates according to the extension coloring
message of the receiving group member. (0~9998, F-STN, NONE)