Selecting Procedure Of Control Mode - Mitsubishi Electric MELSERVO-J4 series Instruction Manual

Servo amplifier mr-j4-_b(-rj) mr-j4-_b4(-rj) mr-j4-_b1(-rj)
Hide thumbs Also See for MELSERVO-J4 series:
Table of Contents

Advertisement

16. FULLY CLOSED LOOP SYSTEM

16.1.2 Selecting procedure of control mode

(1) Control mode configuration
In this servo, a semi closed loop system or fully closed loop system can be selected as a control system.
In addition, on the fully closed loop system, the semi closed loop control, fully closed loop control and
dual feedback control can be selected by the [Pr. PE08] settings.
Operation mode selection
([Pr. PA01])
Servo amplifier
(Refer to section 16.3.1 (2)(a))
(2) Dual feedback filter equivalent block diagram
A dual feedback filter equivalent block diagram on the dual feedback control is shown below.
Fully closed
loop control
Note. "ω" (a dual feedback filter band) is set by [Pr. PE08].
"_ _ 0 _"
"_ _ 1 _"
Fully closed loop
function selection 1
([Pr. PE01])
(Refer to section 16.3.1(2)(b))
+
Position
control unit
-
+
High-pass
filter
+
Low-pass
filter
ω (Note)
Semi closed
loop control
Semi closed/fully closed switching command
(Refer to the controller user's manual.)
OFF
ON
Fully closed loop
"_ _ _ 1"
dual feedback filter
([Pr. PE08])
"_ _ _ 0"
Servo motor
Linear encoder
Operation status
Servo motor during a stop
(0 to ω)
In operation (ω or more)
Frequency [rad/s]
16 - 3
Semi closed loop system
Semi closed
loop control
Fully closed loop system
"0"
Semi closed
loop control
"1 to 4499"
Dual feedback
control
"4500"
Fully closed
loop control
Dual feedback filter
Control status
Fully closed loop
control
Semi closed loop
control

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents