Mitsubishi Electric MELSERVO-J4 series Instruction Manual page 324

Servo amplifier mr-j4-_b(-rj) mr-j4-_b4(-rj) mr-j4-_b1(-rj)
Hide thumbs Also See for MELSERVO-J4 series:
Table of Contents

Advertisement

11. Options and peripheral devices
(b) 400 V class
(Note 7)
MCCB
3-phase
380 V AC to
480 V AC
Step-down
transformer
Note 1. Configure a sequence that will shut off main circuit power in the following.
An alarm occurred at FR-CV-H or servo amplifier.
EM1 (Forced stop 1) is enabled.
2. For the servo amplifier, configure a sequence that will switch the servo-on after the FR-CV-H is ready.
3. For the FR-CV-H, the RSO signal turns off when it is put in a ready-to-operate status where the reset signal is input. Configure
a sequence that will make the servo inoperative when the RSO signal is on.
4. Configure a sequence that will make a stop with the emergency stop input of the servo system controller if an alarm occurs in
the FR-CV-H. When the servo system controller does not have an emergency stop input, use the forced stop input of the servo
amplifier to make a stop as shown in the diagram.
5. When using FR-CV-H, always disconnect wiring between P3 and P4 terminals.
6. Set [Pr. PA04] to "0 0 _ _" to enable EM1 (Forced stop 1).
7. When wires used for L11 and L21 are thinner than wires used for L1, L2, and L3, use a molded-case circuit breaker.
8. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they
can be configured by one.
FR-CVL-H
MC
R/L11
R2/L12
S2/L22
S/L21
T/L31
T2/L32
RESET
(Note 1)
EM1 OFF
RA1
RA2
ON
MC
MC
SK
FR-CV-H
R2/L1
S2/L2
T2/L3
P/L+
N/L-
24 V DC (Note 8)
R/L11
S/L21
P24
T/MC1
SD
Servo system
RES
controller
RDYB
SD
(Note 2)
RDYA
(Note 3)
RSO
SE
(Note 1)
A
RA1
(Note 4)
RA1
B
C
24 V DC (Note 8)
11 - 43
Servo amplifier
Servo motor
U
U
L11
V
V
L21
W
W
CN2
P4
(Note 5)
N-
24 V DC (Note 8)
DOCOM
ALM
(Note 1, 6)
EM1
EM1
DICOM
RA2