1. FUNCTIONS AND CONFIGURATION
(3) 100 V class
The diagram is for MR-J4-20B1-RJ.
R
T
(Note 2)
Power supply
Molded-case
circuit breaker
(MCCB)
(Note 3)
Magnetic
contactor
(MC)
Power factor
(Note 1)
improving AC
reactor
(FR-HAL)
Line noise
filter
(FR-BSF01)
L1
L2
P+
Regenerative
option
C
Note 1. The power factor improving DC reactor cannot be used.
2. For power supply specifications, refer to section 1.3.
3. Depending on the main circuit voltage and operation pattern, bus voltage decreases, and that may cause the forced stop
deceleration to shift to the dynamic brake deceleration. When dynamic brake deceleration is not required, slow the time to turn
off the magnetic contactor.
4. This is for MR-J4-_B1-RJ servo amplifier. MR-J4-_B1 servo amplifier does not have CN2L connector. Refer to Table 1.1 and
Linear Encoder Instruction Manual for the compatible external encoders.
(Note1)
U
V
W
L11
L21
MR Configurator2
CN5
CN3
CN8
CN1A
CN1B
CN2
CN2L (Note 4)
CN4
Battery
1 - 49
Personal
computer
Junction terminal
block
To safety relay or MR-J3-D05
safety logic unit
Servo system controller or
previous servo amplifier
CN1B
Next servo amplifier CN1A or
cap
Servo motor