Mitsubishi Electric MELSERVO-J4 series Instruction Manual page 532

Servo amplifier mr-j4-_b(-rj) mr-j4-_b4(-rj) mr-j4-_b1(-rj)
Hide thumbs Also See for MELSERVO-J4 series:
Table of Contents

Advertisement

APPENDIX
App. 5.13 Installation
Follow the instructions in this section and install MR-J3-D05 in the specified direction. Leave clearances
between MR-J3-D05 and other equipment including the cabinet.
Cabinet
40 mm or
longer
10 mm or
longer
40 mm or
longer
App. 5.14 Combinations of cable/connector
Cabinet
100 mm or longer
10 mm or
longer
30 mm or
longer
40 mm or
longer
POINT
MR-D05UDL_M (STO cable) for MR-J3 series cannot be used.
MR-J3-D05
1)
CN9
CN10
MR-J3-D05
attachment
connector
App. - 35
10 mm or
longer
30 mm or
longer
2)
Cabinet
80 mm or longer
for wiring
MR-J3-D05
MR-J4_B_(-RJ)
CN8
2)
MR-J4_B_(-RJ)
CN8
Top
Bottom

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents