Mitsubishi Electric MELSERVO-J4 series Instruction Manual page 179

Servo amplifier mr-j4-_b(-rj) mr-j4-_b4(-rj) mr-j4-_b1(-rj)
Hide thumbs Also See for MELSERVO-J4 series:
Table of Contents

Advertisement

5. PARAMETERS
No.
Symbol
PD11
*DIF
Input filter setting
Select the input filter.
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PD12
*DOP1
Function selection D-1
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PD14
*DOP3
Function selection D-3
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
Name and function
Explanation
Input signal filter selection
Refer to the servo system controller instruction manual for the
setting.
If external input signal causes chattering due to noise, etc., input
filter is used to suppress it.
0: None
1: 0.888 [ms]
2: 1.777 [ms]
3: 2.666 [ms]
4: 3.555 [ms]
For manufacturer setting
Explanation
For manufacturer setting
Servo motor or linear servo motor thermistor enabled/disabled
selection
(Supported by servo amplifiers with software version A5 or above.)
0: Enabled
1: Disabled
For servo motors or linear servo motor without thermistor, the
setting will be disabled.
Explanation
For manufacturer setting
Selection of output device at warning occurrence
Select WNG (Warning) and ALM (Malfunction) output status at
warning occurrence.
Servo amplifier output
Setting
(Note 1) Device status
value
WNG
0
ALM
1
WNG
0
1
1
ALM
0
Note 1. 0: Off
1: On
2. Although ALM is turned off upon occurrence of the
warning, the forced stop deceleration is performed.
For manufacturer setting
1
0
1
0
Warning occurrence
Warning occurrence (Note 2)
5 - 42
Initial
Setting
value
range
[unit]
Refer to Name
and function
column.
Initial
value
4h
0h
0h
0h
Refer to Name
and function
Initial
column.
value
0h
0h
0h
0h
Refer to Name
and function
Initial
column.
value
0h
0h
0h
0h