Mitsubishi Electric MELSERVO-J4 series Instruction Manual page 506

Servo amplifier mr-j4-_b(-rj) mr-j4-_b4(-rj) mr-j4-_b1(-rj)
Hide thumbs Also See for MELSERVO-J4 series:
Table of Contents

Advertisement

APPENDIX
(6) Protect the cables with appropriate ways (routing them in a cabinet, using a cable guard, etc.).
(7) Keep the required clearance/creepage distance depending on voltage you use.
App. 4.2.6 Disposal
Disposal of unusable or irreparable devices should always occur in accordance with the applicable country-
specific waste disposal regulations. (Example: European Waste 16 02 14)
App. 4.2.7 Lithium battery transportation
To transport lithium batteries, take actions to comply with the instructions and regulations such as the United
Nations (UN), the International Civil Aviation Organization (ICAO), and the International Maritime
Organization (IMO).
The battery options (MR-BAT6V1SET and MR-BAT6V1) are assembled batteries from two batteries (lithium
metal battery CR17335A) which are not subject to the dangerous goods (Class 9) of the UN
Recommendations.
App. 4.3 Mounting/dismounting
Installation direction and clearances
CAUTION
The devices must be installed in the specified direction. Not doing so may cause
a malfunction.
Mount the servo amplifier on a cabinet which meets IP54 in the correct vertical
direction to maintain pollution degree 2.
Note the followings for supplied regenerative resistors of 11 kW to 22 kW servo
amplifiers because they do not have protect covers.
Touching the resistor will cause a burn because the surface of the parts is a
resistive element and very high temperature.
Even if the power turned off, touching the resistor will cause an electric shock
because the capacitor of the servo amplifier is charged for a while.
10 mm
or more
(Note 2)
Note 1. For 11 kW to 22 kW servo amplifiers, the clearance between the bottom and
ground will be 120 mm or more.
2. For MR-J4-500_, the clearance on the left side will be 25 mm or more.
Cabinet
Top
40 mm
or more
10 mm
or more
40mm
or more
(Note 1)
Bottom
App. - 9
Cabinet
80 mm or longer
for wiring
Servo amplifier

Hide quick links: