Mitsubishi Electric MELSERVO-J4 series Instruction Manual page 160

Servo amplifier mr-j4-_b(-rj) mr-j4-_b4(-rj) mr-j4-_b1(-rj)
Hide thumbs Also See for MELSERVO-J4 series:
Table of Contents

Advertisement

5. PARAMETERS
No.
Symbol
PB06
GD2
Load to motor inertia ratio/load to motor mass ratio
This is used to set the load to motor inertia ratio or load to motor mass ratio.
The setting of the parameter will be the automatic setting or manual setting depending on the
[Pr. PA08] setting. Refer to the following table for details. When the parameter is automatic
setting, the value will vary between 0.00 and 100.00.
_ _ _ 0 (2 gain adjustment mode 1 (interpolation mode))
_ _ _ 1 (Auto tuning mode 1)
_ _ _ 2 (Auto tuning mode 2)
_ _ _ 3 (Manual mode)
_ _ _ 4 (2 gain adjustment mode 2)
PB07
PG1
Model loop gain
Set the response gain up to the target position.
Increasing the setting value will also increase the response level to the position command but
will be liable to generate vibration and/or noise.
The setting of the parameter will be the automatic setting or manual setting depending on the
[Pr. PA08] setting. Refer to the following table for details.
_ _ _ 0 (2 gain adjustment mode 1 (interpolation mode))
_ _ _ 1 (Auto tuning mode 1)
_ _ _ 2 (Auto tuning mode 2)
_ _ _ 3 (Manual mode)
_ _ _ 4 (2 gain adjustment mode 2)
PB08
PG2
Position loop gain
This is used to set the gain of the position loop.
Set this parameter to increase the position response to level load disturbance.
Increasing the setting value will also increase the response level to the load disturbance but
will be liable to generate vibration and/or noise.
The setting of the parameter will be the automatic setting or manual setting depending on the
[Pr. PA08] setting. Refer to the following table for details.
_ _ _ 0 (2 gain adjustment mode 1 (interpolation mode))
_ _ _ 1 (Auto tuning mode 1)
_ _ _ 2 (Auto tuning mode 2)
_ _ _ 3 (Manual mode)
_ _ _ 4 (2 gain adjustment mode 2)
PB09
VG2
Speed loop gain
This is used to set the gain of the speed loop.
Set this parameter when vibration occurs on machines of low rigidity or large backlash.
Increasing the setting value will also increase the response level but will be liable to generate
vibration and/or noise.
The setting of the parameter will be the automatic setting or manual setting depending on the
[Pr. PA08] setting. Refer to the table of [Pr. PB08] for details.
PB10
VIC
Speed integral compensation
This is used to set the integral time constant of the speed loop.
Decreasing the setting value will increase the response level but will be liable to generate
vibration and/or noise.
The setting of the parameter will be the automatic setting or manual setting depending on the
[Pr. PA08] setting. Refer to the table of [Pr. PB08] for details.
Name and function
Pr. PA08
Pr. PA08
Pr. PA08
5 - 23
This parameter
Automatic setting
Manual setting
This parameter
Manual setting
Automatic setting
Manual setting
This parameter
Automatic setting
Manual setting
Automatic setting
Initial
Setting
value
range
[unit]
7.00
0.00 to
Multiplier
300.00
15.0
1.0 to
[rad/s]
2000.0
37.0
1.0 to
[rad/s]
2000.0
823
20 to
[rad/s]
65535
33.7
0.1 to
[ms]
1000.0

Hide quick links:

Advertisement

Table of Contents
loading