1. FUNCTIONS AND CONFIGURATION

1.5 Selecting procedure of control mode

1.5.1 Control mode configuration

In this servo, a semi closed loop system or fully closed loop system can be selected as a control system.
Also, on the fully closed loop system, the semi closed loop control, fully closed loop control and dual feedback
control can be switched by the parameter No.PE08 settings.
Control mode selection
Parameter No.PA01
MR-J3- B-RJ006
(Refer to section 5.1.3.)

1.5.2 Dual feedback filter equivalent block diagram

A dual feedback filter equivalent block diagram on the dual feedback control is shown below.
Fully closed
loop control
Note.
(a dual feedback filter band) is set by parameter No.PE08.
0
1
Fully closed loop
Selection 1
Parameter No.PE01
(Refer to section 5.5.2.)
Positioning
controller
High-pass
filter
Low-pass
filter
(Note)
Semi closed
loop control
Frequency [rad/s]
Controller command
Semi closed loop control/
fully closed loop control switching bit
Fully closed loop dual
1
feedback filter
Parameter No.PE08
0
Servo motor
Linear encoder
<Dual feedback filter>
Operating status
At motor stop (0 to
At operating (from
1 - 6
Semi closed loop system
Semi closed loop
control
OFF
ON
Fully closed loop system
0000
Semi closed loop
control
Dual feedback
0001 to 4499
control
4500
Fully closed loop
control
Controlling status
) Fully closed loop control
Semi closed loop control
)