Mitsubishi Electric MELSERVO-J4 series Instruction Manual page 512

Servo amplifier mr-j4-_b(-rj) mr-j4-_b4(-rj) mr-j4-_b1(-rj)
Hide thumbs Also See for MELSERVO-J4 series:
Table of Contents

Advertisement

APPENDIX
App. 4.7 Transportation and storage
CAUTION
When you keep or use it, please fulfill the following environment.
Item
Operation
Ambient
Transportation (Note)
temperature
Storage (Note)
Ambient
Operation,
humidity
transportation, storage
Test condition
Vibration
resistance
Operation
Transportation (Note)
Storage
Pollution degree
IP rating
Operation, storage
Altitude
Transportation
Note. In regular transport packaging
Transport the products correctly according to their mass.
Stacking in excess of the limited number of product packages is not allowed.
Do not hold the front cover to transport the servo amplifier. Otherwise, it may
drop.
Install the servo amplifier and servo motor in a load-bearing place in accordance
with the Instruction Manual.
Do not get on or put heavy load on the equipment.
For detailed information on the option battery's transportation and handing, refer
to app. 2 and app. 3.
[°C]
[°C]
[°C]
57 Hz to 150 Hz with constant acceleration of 9.8 m/s
Fc of IEC 60068-2-6)
Except terminal block IP20 (IEC/EN 60529) and fan finger guard
Environment
0 to 55 Class 3K3 (IEC/EN 60721-3-3)
-20 to 65 Class 2K4 (IEC/EN 60721-3-2)
-20 to 65 Class 1K4 (IEC/EN 60721-3-1)
5% to 90 %RH
10 Hz to 57 Hz with constant amplitude of 0.075 mm
2
5.9 m/s
Class 2M3 (IEC/EN 60721-3-2)
Class 1M2 (IEC/EN 60721-3-2)
2
Open type (UL 50)
1000 m or less above sea level
10000 m or less above sea level
App. - 15
2
(1 g) to IEC/EN 61800-5-1 (Test
(0.6 g)