APPENDIX

App. 7 How to replace servo amplifier without magnetic pole detection

CAUTION
When replacing the servo amplifier, carry out the magnetic pole detection again. If the magnetic pole
detection cannot be performed unavoidably, write the magnetic pole information from the servo amplifier
before the replacement to the one after the replacement using MR Configurator2.
(1) Procedures
(a) Read the magnetic pole information of the servo amplifier before the replacement.
(b) Write the read magnetic pole information to the servo amplifier after the replacement.
(c) Perform the test operation with the torque limit for ensuring the safety, and confirm that there is no
trouble.
(2) Migration method of the magnetic pole information
(a) How to read the magnetic pole information from the servo amplifier before the replacement
1) Open the project in MR Configurator2, select "MR-J4-B" for model, and select "Linear" for
operation mode.
2) Check that the personal computer is connected with the servo amplifier, and select "Diagnosis"
and then "Linear diagnosis".
3) Click the "Magnetic pole information" button ( 1) in figure) to open the magnetic pole information
window.
4) Click "Read All" of the magnetic pole information window. ( 2) in figure)
5) Confirm the data 1 and data 2 ( 3) in figure) of the magnetic pole information window and take
notes.
(b) How to write the magnetic pole information to the servo amplifier after the replacement
1) Open the project in MR Configurator2, select "MR-J4-B" for model, and select "Linear" for
operation mode.
2) Check that the personal computer is connected with the servo amplifier, and select "Diagnosis"
and then "Linear diagnosis".
3) Click the "Magnetic pole information" button ( 1) in figure) to open the magnetic pole information
window.
4) Input the value of the magnetic pole information taken notes to the data 1 and data 2 ( 3) in
figure) of the magnetic pole information window.
5) Click "Write All" ( 4) in figure) of the magnetic pole information window.
6) Cycle the power of the servo amplifier.
Be sure to write the magnetic pole information of the servo amplifier before the
replacement to the servo amplifier after the replacement. If the information before
and after replacement are not the same, the servo motor may operate
unexpectedly.