16. FULLY CLOSED LOOP SYSTEM
(6) Confirmation of load-side encoder position data
Check the load-side encoder mounting and parameter settings for any problems.
When checking the following items, the fully closed loop control mode must be set. For the setting of
control mode, refer to (2) in this section.
No.
Check item
1
Read of load-side encoder position
data
2
Read of load-side encoder scale
home position (reference mark, Z-
phase)
3
Confirmation of load-side encoder
feedback direction
(Setting of load-side encoder
polarity)
4
Setting of load-side encoder
electronic gear
POINT
Depending on the check items, MR Configurator2 may be used.
Refer to section 16.3.9 for the data displayed on the MR Configurator2.
With the load-side encoder in a normal state (mounting, connection, etc.), the load-side
cumulative feedback pulses value is counted normally when the load-side encoder is
moved.
1. An alarm occurred.
2. The installation of the load-side encoder was not correct.
3. The encoder cable was not wired correctly.
With the home position (reference mark, or Z-phase) of the load-side encoder in a normal
condition (mounting, connection, etc.), the value of load-side encoder information 1 is
cleared to 0 when the home position (reference mark, or Z-phase) is passed through by
moving the load-side encoder.
1. The installation of the load-side encoder was not correct.
2. The encoder cable was not wired correctly.
Confirm that the directions of the cumulative feedback pulses of servo motor encoder (after
gear) and the load-side cumulative feedback pulses are matched by moving the device
(load-side encoder) manually in the servo-off status. If mismatched, reverse the polarity.
When the servo motor and load-side encoder operate synchronously, the servo motor-side
cumulative feedback pulses (after gear) and load-side cumulative feedback pulses are
matched and increased.
If mismatched, review the setting of fully closed loop control feedback electronic gear ([Pr.
PE04], [Pr. PE05], [Pr. PE34], and [Pr. PE35]) with the following method.
1) Check the servo motor-side cumulative feedback pulses (before gear).
2) Check the load-side cumulative feedback pulses.
3) Check that the ratio of above 1) and 2) has been that of the feedback electronic gear.
Servo motor-side cumulative
feedback pulses (after gear)
2) Load-side cumulative
feedback pulses
Confirmation method and description
+
Command
-
3) Electronic
gear
1) Servo motor-side cumulative
feedback pulses (before gear)
16 - 14
Servo motor
Linear
encoder