Mitsubishi Electric MELSERVO-J4 series Instruction Manual page 328

Servo amplifier mr-j4-_b(-rj) mr-j4-_b4(-rj) mr-j4-_b1(-rj)
Hide thumbs Also See for MELSERVO-J4 series:
Table of Contents

Advertisement

11. Options and peripheral devices
Item
Total of connectable servo amplifier
capacities
Maximum servo amplifier capacity
IP rating (JEM 1030), cooling method
Altitude, vibration resistance
Molded-case circuit breaker or earth-
leakage current breaker
Magnetic contactor
Note 1. This is the time when the protective function of the FR-CV-(H) is activated. The protective function of
Power regeneration common
converter FR-CV-H_
Total of connectable servo
motor rated currents
Short-time rating
Regenerative
braking torque
Continuous rating
Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Power supply capacity (Note 2) [kVA]
Ambient temperature
Ambient humidity
Ambience
the servo amplifier is activated in the time indicated in section 10.1.
2. The specified value is the power supply capacity of FR-CV-(H). The total power supply capacities of
the connected servo amplifiers are actually required.
22K
[kW]
11
[kW]
11
[A]
43
Total capacity of applicable servo motors, 300% torque, 60 s
3-phase 380 V AC to 480 V AC, 50 Hz/60 Hz
3-phase 323 V AC to 528 V AC, 50 Hz/60 Hz
41
Open type (IP00), forced cooling
-10 ˚C to 50 ˚C (non-freezing)
90 %RH or less (non-condensing)
Indoors (no direct sunlight), free from corrosive gas,
flammable gas, oil mist, dust, and dirt
1000 m or less above sea level, 5.9 m/s
50AF
50A
S-N25
11 - 47
30K
37K
15
185
15
15
57
71
(Note 1)
100% torque
±5%
52
66
60AF
100AF
60A
75A
S-N35
S-N50
55K
27.5
22
110
100
2
100AF
100A
S-N65