Basler BE1-11g Instruction Manual page 665

Generator protection system
Hide thumbs Also See for BE1-11g:
Table of Contents

Advertisement

9424200994 Rev N
Firmware
Version and Date
2.07.00, Nov-13
2.08.00, Apr-14
2.08.01, May-14
2.08.02, Aug-14
Software
Version and Date
2.04.01, May-09
BE1-11g
Made alarms available in BESTlogicPlus
Expanded Target Reset logic point to operate from all target
reset requests
Added an option to Modbus to perform group saves to reduce
write times
Made Settings Group available in scrolling screens
Added Power Loss alarm
Eight additional 49RTD elements
Improved 60FL coordination when upstream breakers open
Improved tracking of failed login attempts with bad user names
Improved reporting of breaker operate time
Added logic nodes and made minor improvements to IEC 61850
protocol
Added a Language Selection setting to choose language for the
front-panel display
Added Russian language option
Corrected accuracy of 25A voltage monitor dropout timer and
slip frequency
Updated Time Dial range for IEC curves in the 51 element
Improved 78V for frequency out-of-range operation
Added output hold timer to 78V
Improved Frequency Out-of-Range alarm to indicate when any
source is out of range instead of when all sources are out of
range
Improved 60FL operation to prevent chance of nuisance alarm
during settings group change
Improved 40Q operation for single-phase connections
Improved Modbus response to reads with incorrect ID
Changed clock priority setup to prevent user from accidentally
disabling internal real-time clock
Corrected issue that prevented front-panel select and operate
switches from operating the 43 switches
Corrected placement of data on scrolling metering screens
Added missing characters to scrolled metering screen
Corrected shifted HMI screen headings for Watts/vars, VA/PF,
and Dip/Swell
Corrected unsecured access on non BESTCOMSPlus ports
Made default state of 61850 inputs available at all times
Improved IRIG accuracy
Corrected the function of the Block input for Analog Input
Protection elements
Improved display of oscillographic records for 3W and 4W
configurations
Removed blank screen from scrolling metering when 6 metering
values are selected
Corrected uploading of a blank CID file for 61850
Table 262. BESTCOMSPlus® Software Revision History
Initial release