Using The Digital Operator; Using The Digital Operator; Digital Operator Keys And Displays - YASKAWA P1000 Technical Manual

Models: 200 v class: 3/4 to 175 hp nd 400 v class: 3/4 to 1000 hp nd 600 v class: 1 to 250 hp nd
Hide thumbs Also See for P1000:
Table of Contents

Advertisement

4.2

Using the Digital Operator

Use the digital operator to enter Run and Stop commands, edit parameters, and display data including fault and alarm
information.
u

Digital Operator Keys and Displays

No.
Display
F1
Function Key
1
(F1, F2)
F2
2
ESC Key
ESC
3
RESET Key
4
RUN Key
RUN
5
Up Arrow Key
6
Down Arrow Key
7
STOP
STOP Key
8
ENTER Key
9
LO/RE Selection Key
10
RUN Light
11
LO/RE Light
12
ALM LED Light
<1> The STOP key has highest priority. Pressing the STOP key will always cause the drive to stop the motor, even if a Run command is active at any
external Run command source. To disable the STOP key priority, set parameter o2-02 to 0.
<2> The LO/RE key can only switch between LOCAL and REMOTE when the drive is stopped. To disable the LO/RE key to prohibit switching between
LOCAL and REMOTE, set parameter o2-01 to 0.
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
DIGITAL OPERATOR
1
F1
2
ESC
3
RESET
10
RUN
4
5 6
Figure 4.1 Keys and Displays on the Digital Operator
Name
The functions assigned to F1 and F2 vary depending on the currently displayed menu. The
name of each function appears in the lower half of the display window.
• Returns to the previous display.
• Moves the cursor one space to the left.
• Pressing and holding this button will return to the Frequency Reference display.
• Moves the cursor to the right.
• Resets the drive to clear a fault situation.
Starts the drive in LOCAL mode.
Scrolls up to display the next item, selects parameter numbers, and increments setting
values.
Scrolls down to display the previous item, selects parameter numbers, and decrements
setting values.
<1>
Stops drive operation.
• Enters parameter values and settings.
• Selects a menu item to move between displays
Switches drive control and frequency setting between the operator (LOCAL) and an
<2>
external source (REMOTE).
Lit while the drive is operating the motor. Refer to page
Lit while the operator is selected to run the drive (LOCAL mode). Refer to page
details.
Refer to ALARM (ALM) LED Displays on page

4.2 Using the Digital Operator

12
ALM
11
F2
9
LO
RE
8
ENTER
STOP
7
Function
111
for details.
111
111.
4
for
109

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents