Using The Digital Operator; Using The Digital Operator; Keys And Displays - YASKAWA FSDrive-MV1000 Instructions Manual

Super energy-saving medium-voltage ac drive
Hide thumbs Also See for FSDrive-MV1000:
Table of Contents

Advertisement

4.2

Using the Digital Operator

Use the digital operator to enter run and stop commands, display data, edit parameters, as well as display fault and alarm
information.

◆ Keys and Displays

Figure 4.1
No.
Key
Name
F1
Function Key
1
(F1, F2)
F2
2
ESC Key
3
RESET Key
4
RUN Key
RUN
5
Up Arrow Key
6
Down Arrow Key
7
STOP Key
STOP
8
ENTER Key
LO/RE Selection
9
Key
<2>
10
RUN Light
11
LO/RE Light
LO
RE
12
ALM LED Light
<1> The STOP key has highest priority.
The drive can be stopped in an emergency stop status by pressing the
command source. To disable the
<2> The LO/RE key can only switch between LOCAL and REMOTE when the drive is stopped.
To disable the
key to prohibit switching between LOCAL and REMOTE, set parameter o2-01 to 0.
LO
RE
YASKAWA ELECTRIC EZZ010928 FSDrive-MV1000 Instructions
DIGITAL OPERATOR JVOP-180
1
F1
2
ESC
3
RESET
10
RUN
4
Figure 4.1 Keys and Displays on the Digital Operator
The functions assigned to F1 and F2 vary depending on the menu that is currently displayed. The
name of each function appears in the lower half of the display window. Refer to
page 80
for the details of the functions assigned.
• Returns to the previous display.
• Moves the cursor one space to the left.
• Pressing and holding this button will return to the Frequency Reference display.
• Moves the cursor to the right.
• Resets the drive to clear a fault situation.
Runs the drive in the LOCAL mode.
• Scrolls up to display the next item.
• Selects parameter numbers and increments setting values.
• Scrolls down to display the next item.
• Selects parameter numbers and decrements setting values.
Stops drive operation.
<1>
• Enters parameter values and settings.
• Selects a menu item to move between displays.
Switches drive control between the digital operator (LOCAL) and the control circuit terminals
(REMOTE).
Lit while the drive is operating the motor. Refer to
the details.
Lit while the digital operator is selected to run the drive (LOCAL mode).
Refer to
ALARM (ALM) LED Displays on page 81
key priority, set parameter o2-02 to 0.
12
ALM
11
F2
LO
9
RE
8
ENTER
STOP
5
6
7
Function
ALARM (ALM) LED Displays on page 81
for the details.
key, even if a Run command is active at any external Run

4.2 Using the Digital Operator

LCD Display on
for
4
79

Hide quick links:

Advertisement

Table of Contents
loading