806f040c-08850005 • 806f040c-08850006
806f040c-08850005 [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName].
Explanation: DIMM 5 in mem card 5 has been Disabled.
May also be shown as 806f040c08850005 or 0x806f040c08850005
Severity: Info
Alert Category: System
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1. Make sure the DIMM is installed correctly.
2. If the DIMM was disabled because of a memory fault, follow the suggested actions for that error event and restart
the server.
3. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM
through the Setup utility or the Advanced Settings Utility (ASU).
806f040c-08850006 [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName].
Explanation: DIMM 6 in mem card 5 has been Disabled.
May also be shown as 806f040c08850006 or 0x806f040c08850006
Severity: Info
Alert Category: System
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1. Make sure the DIMM is installed correctly.
2. If the DIMM was disabled because of a memory fault, follow the suggested actions for that error event and restart
the server.
3. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM
through the Setup utility or the Advanced Settings Utility (ASU).