IBM X3950 X5 Problem Determination And Service Manual page 638

Types 7145, 7146, 7143, and 7191
Hide thumbs Also See for X3950 X5:
Table of Contents

Advertisement

806f040c-18810019 • 806f040c-1881001a
806f040c-18810019 [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName].
Explanation: DIMM 25 in memory expansion module(MEU) has been Disabled.
May also be shown as 806f040c18810019 or 0x806f040c18810019
Severity: Info
Alert Category: System
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1. Make sure the DIMM is installed correctly.
2. If the DIMM was disabled because of a memory fault, follow the suggested actions for that error event and restart
the server.
3. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM
through the Setup utility or the Advanced Settings Utility (ASU).
806f040c-1881001a [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName].
Explanation: DIMM 26 in memory expansion module(MEU) has been Disabled.
May also be shown as 806f040c1881001a or 0x806f040c1881001a
Severity: Info
Alert Category: System
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1. Make sure the DIMM is installed correctly.
2. If the DIMM was disabled because of a memory fault, follow the suggested actions for that error event and restart
the server.
3. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM
through the Setup utility or the Advanced Settings Utility (ASU).
622
IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide

Hide quick links: