816f0008-1881ffff • 816f000d-0400ffff
816f0008-1881ffff [PowerSupplyElementName] has been removed from container [PhysicalPackageElementName].
Explanation: MEU Power supple has been removed.
May also be shown as 816f00081881ffff or 0x816f00081881ffff
Severity: Info
Alert Category: System
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0085
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is required.
816f0009-1381ffff [PowerSupplyElementName] has been turned on.
Explanation: IMM has detected that the system power has been turned on.
May also be shown as 816f00091381ffff or 0x816f00091381ffff
Severity: Info
Alert Category: System
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0107
SNMP Trap ID: 24
Automatically notify Support: No
User response: No action; information only.
816f000d-0400ffff The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName].
Explanation: Presence of drive 0 is no longer detected. If hard drive is absent from drive bay a filler is required.
May also be shown as 816f000d0400ffff or 0x816f000d0400ffff
Severity: Info
Alert Category: System
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0163
SNMP Trap ID: 22
Automatically notify Support: No
User response:
v If drive was intentionally removed, no action required.
v Make sure that the drive properly seated.
v If drive is properly seated, replace the drive.
783