816f000d-040dffff • 816f000d-040effff
816f000d-040dffff The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName].
Explanation: Presence of drive 13 is no longer detected. If hard drive is absent from drive bay a filler is required.
May also be shown as 816f000d040dffff or 0x816f000d040dffff
Severity: Info
Alert Category: System
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0163
SNMP Trap ID: 22
Automatically notify Support: No
User response:
v If drive was intentionally removed, no action required.
v Make sure that the drive properly seated.
v If drive is properly seated, replace the drive.
816f000d-040effff The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName].
Explanation: Presence of drive 14 is no longer detected. If hard drive is absent from drive bay a filler is required.
May also be shown as 816f000d040effff or 0x816f000d040effff
Severity: Info
Alert Category: System
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0163
SNMP Trap ID: 22
Automatically notify Support: No
User response:
v If drive was intentionally removed, no action required.
v Make sure that the drive properly seated.
v If drive is properly seated, replace the drive.