81070204-1881ffff • 81070301-0301ffff
81070204-1881ffff Sensor [SensorElementName] has transitioned to a less severe state from critical.
Explanation: MEU power supply fan transition to less severe from critical
May also be shown as 810702041881ffff or 0x810702041881ffff
Severity: Info
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0523
SNMP Trap ID: 11
Automatically notify Support: No
User response: No action; information only.
81070208-1881ffff Sensor [SensorElementName] has transitioned to a less severe state from critical.
Explanation: Memory expansion module power failure transitioned to a less severe state from critical.
May also be shown as 810702081881ffff or 0x810702081881ffff
Severity: Info
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0523
SNMP Trap ID: 4
Automatically notify Support: No
User response: No action; information only.
81070301-0301ffff Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less
severe state.
Explanation: The microprocessor 1 temperature has returned to below its specified threshold.
May also be shown as 810703010301ffff or 0x810703010301ffff
Severity: Info
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0525
SNMP Trap ID: 0
Automatically notify Support: No
User response: No action; information only.