IBM X3950 X5 Problem Determination And Service Manual page 420

Types 7145, 7146, 7143, and 7191
Hide thumbs Also See for X3950 X5:
Table of Contents

Advertisement

80070201-0303ffff • 80070201-0304ffff
80070201-0303ffff Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: IMM has detected a CPU 3 temperature Sensor has transitioned to critical.
May also be shown as 800702010303ffff or 0x800702010303ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80070201-0304ffff Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: IMM has detected a CPU 4 temperature Sensor has transitioned to critical.
May also be shown as 800702010304ffff or 0x800702010304ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
404