806f070c-2586ffff • 806f070c-2588ffff
806f070c-2586ffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Explanation: A memory configuration (memory card 1 bank) error has occurred.
May also be shown as 806f070c2586ffff or 0x806f070c2586ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure the memory cards are installed in the correct sequence.
806f070c-2587ffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Explanation: A memory configuration (memory card 2 bank) error has occurred.
May also be shown as 806f070c2587ffff or 0x806f070c2587ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure the memory cards are installed in the correct sequence.
806f070c-2588ffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Explanation: A memory configuration (memory card 3 bank) error has occurred.
May also be shown as 806f070c2588ffff or 0x806f070c2588ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure the memory cards are installed in the correct sequence.