IBM X3950 X5 Problem Determination And Service Manual page 526

Types 7145, 7146, 7143, and 7191
Hide thumbs Also See for X3950 X5:
Table of Contents

Advertisement

806f010d-0406ffff • 806f010d-0407ffff
806f010d-0406ffff The Drive [StorageVolumeElementName] has been disabled due to a detected fault.
Explanation: The drive 6 has been disabled (defunct) due to a fault detected by the controller.
May also be shown as 806f010d0406ffff or 0x806f010d0406ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0164
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
2. Check IBM Support site for firmware updates related to your particular drive.
3. Check for any other RAID related errors.
4. Replace the drive.
806f010d-0407ffff The Drive [StorageVolumeElementName] has been disabled due to a detected fault.
Explanation: The drive 7 has been disabled (defunct) due to a fault detected by the controller.
May also be shown as 806f010d0407ffff or 0x806f010d0407ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0164
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
2. Check IBM Support site for firmware updates related to your particular drive.
3. Check for any other RAID related errors.
4. Replace the drive.
510
IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X3850 x5

Table of Contents