80070608-1412ffff • 80070608-1414ffff
80070608-1412ffff Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: A system power fault has occurred.
May also be shown as 800706081412ffff or 0x800706081412ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response: (Trained service technician only) Replace the I/O-board shuttle.
80070608-1413ffff Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: A fault has occurred on the I/O board.
May also be shown as 800706081413ffff or 0x800706081413ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response: (Trained service technician only) Replace the I/O-board shuttle.
80070608-1414ffff Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: A system power fault has occurred.
May also be shown as 800706081414ffff or 0x800706081414ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response: (Trained service technician only) Replace the CPU board.