800b050a-1e83ffff • 800b050c-2581ffff
800b050a-1e83ffff Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.
Explanation: Insufficient cooling provided by fan 3.
May also be shown as 800b050a1e83ffff or 0x800b050a1e83ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0810
SNMP Trap ID: 11
Automatically notify Support: No
User response: Replace Fan 3
800b050a-1e84ffff Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.
Explanation: Insufficient cooling provided by fan 4.
May also be shown as 800b050a1e84ffff or 0x800b050a1e84ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0810
SNMP Trap ID: 11
Automatically notify Support: No
User response: Replace Fan 4
800b050c-2581ffff Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.
Explanation: Backup Memory Sensor has transitioned to Non-redundant:Insufficient Resources.
May also be shown as 800b050c2581ffff or 0x800b050c2581ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0810
SNMP Trap ID: 41
Automatically notify Support: No
User response:
1. Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the failures.
2. Re-enable mirroring in the Setup utility.