806f0807-0304ffff • 806f0813-1801ffff
806f0807-0304ffff [ProcessorElementName] has been Disabled.
Explanation: IMM has detected that Processor 4 has been disabled.
May also be shown as 806f08070304ffff or 0x806f08070304ffff
Severity: Info
Alert Category: System
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0061
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is required.
806f0807-2584ffff [ProcessorElementName] has been Disabled.
Explanation: One of CPUs has been disabled.
May also be shown as 806f08072584ffff or 0x806f08072584ffff
Severity: Info
Alert Category: System
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0061
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is required.
806f0813-1801ffff A Uncorrectable Bus Error has occurred on system [ComputerSystemElementName].
Explanation: IMM has detected a bus uncorrectable error.
May also be shown as 806f08131801ffff or 0x806f08131801ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0240
SNMP Trap ID: 50
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.