IBM X3950 X5 Problem Determination And Service Manual page 762

Types 7145, 7146, 7143, and 7191
Hide thumbs Also See for X3950 X5:
Table of Contents

Advertisement

806f0a0c-258effff • 806f0a0c-258fffff
806f0a0c-258effff An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
Explanation: IMM has detected an over temperature condition on the MEU bank 1.
May also be shown as 806f0a0c258effff or 0x806f0a0c258effff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response: Complete the following steps:
1. Check the IMM event log for any fan, cooling, or power related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
806f0a0c-258fffff An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
Explanation: IMM has detected an over temperature condition on the MEU bank 2.
May also be shown as 806f0a0c258fffff or 0x806f0a0c258fffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response: Complete the following steps:
1. Check the IMM event log for any fan, cooling, or power related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
746
IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X3850 x5

Table of Contents