IBM X3950 X5 Problem Determination And Service Manual page 743

Types 7145, 7146, 7143, and 7191
Hide thumbs Also See for X3950 X5:
Table of Contents

Advertisement

806f070c-258cffff • 806f070d-0400ffff
806f070c-258cffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Explanation: A memory configuration (memory card 7 bank) error has occurred.
May also be shown as 806f070c258cffff or 0x806f070c258cffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure the memory cards are installed in the correct sequence.
806f070c-258dffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Explanation: A memory configuration (memory card 8 bank) error has occurred.
May also be shown as 806f070c258dffff or 0x806f070c258dffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure the memory cards are installed in the correct sequence.
806f070d-0400ffff Rebuild in progress for Array in system [ComputerSystemElementName].
Explanation: IMM has detected that an Array Rebuild is in Progress.
May also be shown as 806f070d0400ffff or 0x806f070d0400ffff
Severity: Info
Alert Category: System
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0178
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is required.